74
FEM610 |
PROCESSMASTER | OI/FEM610-EN REV. A
10 . . .Repair
Loading the system data
Returning devices
Use the original packaging or a secure transport container
of an appropriate type if you need to return the device for
repair or recalibration purposes. Fill out the return form (see
the Appendix) and include this with the device.
According to the EU Directive governing hazardous
materials, the owner of hazardous waste is responsible for
its disposal or must observe the following regulations for
shipping purposes:
All devices delivered to ABB must be free from any
hazardous materials (acids, alkalis, solvents, etc.).
Please contact Customer Center Service listed on page 4 for
nearest service location.
1
Switch on the power supply.
The LCD display shows the following message during
startup process:
During this time the transmitter loads sensor data and
transmitter settings such as flow range, damping and pulse
width from the SensorMemory1).
2
The process display is shown once startup process is
completed.
3
The flowmeter is ready for operation with settings as
received from the factory To change the settings, refer
to chapter "Parameterization of the device" on page 28.
Note
Check and make sure that the parameter settings are
correct.
1) The SensorMemory is a pluggable data memory. It is located on the
rear side of the transmitter electronic.
System Startup
Processing