Note/Illustration
Action
xx1900001496
Remove the screws and lift out the robot
signal exchange proxy.
4
Refitting the robot signal exchange proxy
Refitting the robot signal exchange proxy
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
2
xx1900001446
Continues on next page
Product manual - OmniCore C90XT
195
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.4 Replacing the robot signal exchange proxy
Continued