5.2.3.1 Replacing the standard fans
5.2.3.1.1 Replacing the standard fan
Removing the standard fan
Preparations
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
.
Open the door.
2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
3
xx1900001446
Removing the standard fan
Note/Illustration
Action
Disconnect standard fan:
•
G1.X2-K2.X17
1
xx1900001488
Remove the fan bracket screws.
2
Continues on next page