Note/Illustration
Action
xx1900001879
Insert the cable ties into the locking
holes.
4
Refitting the main computer assembly to the cabinet
Note/Illustration
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
When handling the computer outside of
the controller, use the wrist strap button
located on the side of the computer.
2
xx1900001446
Continues on next page
Product manual - OmniCore C90XT
275
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.12 Replacing the fieldbus master
Continued