Note
The Firewall Manager settings must be set to YES if the EtherNet/IP is to be used
on the public network. Configuration is done in RobotStudio under
Configuration
-> Communication -> Firewall Manager
. See
Operating manual - Integrator's
guide OmniCore
for more information.
Defining network settings
Network settings can be defined either in RobotStudio or from the FlexPendant
for the controller:
•
Defining network settings in RobotStudio:
1 In the
Configuration
browser, right-click the controller and select
Properties
and then
Network settings
.
xx2000000488
2 In the
Network settings
window, set the values for:
-
IP address
: The IP address for the OmniCore controller on the
EtherNet network.
-
Subnet mask
: The subnet mask.
-
Default gateway
: The default gateway.
xx2000000489
Continues on next page
82
Product manual - OmniCore C90XT
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
3 Installation and commissioning
3.5.7 Network connections on OmniCore
Continued