Note/Illustration
Action
Screws: Screw with flange M3x6 (1 pcs)
Secure the fieldbus adapter with the
screw.
3
xx1900001910
Note
The Connected Services Gateway and Ether-
net extension switch are omitted on the illus-
tration to make it more clear.
Screws: Hexalobular socket pan head screw
M3x6 (4 pcs)
Refit the cover of the main computer and
secure the screws.
4
xx1900001909
Note
The Connected Services Gateway and Ether-
net extension switch are omitted on the illus-
tration to make it more clear.
Continues on next page
Product manual - OmniCore C90XT
273
3HAC073706-001 Revision: D
© Copyright 2020-2021 ABB. All rights reserved.
5 Repair
5.2.12 Replacing the fieldbus master
Continued