The following routines are available for the Axis Calibration method:
•
Fine calibration
•
Update revolution counters
•
Reference calibration
The calibration equipment for Axis Calibration is delivered as a toolkit.
An introduction to the calibration method is given in this manual, see
with Axis Calibration method on page 805
The actual instructions of how to perform the calibration procedure and what to
do at each step is given on the FlexPendant. You will be guided through the
calibration procedure, step by step.
CalibWare - Absolute Accuracy calibration
To achieve a good positioning in the Cartesian coordinate system, Absolute
Accuracy calibration is used as a TCP calibration. The CalibWare tool guides
through the calibration process and calculates new compensation parameters.
This is further detailed in the
Application manual - CalibWare Field 5.0
.
If a service operation is done to a robot with the option Absolute Accuracy, a new
absolute accuracy calibration is required in order to establish full performance.
For most cases after motor and transmission replacements that do not include
taking apart the robot structure, standard calibration is sufficient. Standard
calibration also supports wrist exchange.
References
Article numbers for the calibration tools are listed in the section
.
Product manual - IRB 8700
797
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
5 Calibration
5.1.2 Calibration methods
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Product manual IRB 8700 ...
Page 16: ...This page is intentionally left blank ...
Page 824: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 840: ...This page is intentionally left blank ...
Page 846: ......
Page 847: ......