Removing the motor
Use these procedures to remove the motor.
Preparations before removing the axis-4 motor
Note
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
1
Jog the robot into the best position for re-
placing the axis-4 motor.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
3
Disconnecting the axis-4 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001135
Unscrew the attachment screws and
washers and remove the motor cover.
2
Continues on next page
592
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.7.3 Replacing the axis-4 motor
Continued