![ABB IRC5 Compact Product Manual Download Page 815](http://html.mh-extra.com/html/abb/irc5-compact/irc5-compact_product-manual_3087815.webp)
Unsynchronized speed exceeded - SafeMove message while saving robot data
Note
Action
SafeMove generates the message "Unsynchron-
ized speed exceeded" while saving robot data.
xx1500002481
1
Press
Acknowledge
to continue Axis Calibration
procedure.
2
Restart Axis Calibration procedure by pressing
Play
.
3
Unsynchronized time limit expired - SafeMove message anytime during Axis Calibration routine
Note
Action
SafeMove generates the message "Unsynchron-
ized time limit expired" (anytime).
xx1500002482
1
Press
OK
to continue Axis Calibration procedure.
2
Restart Axis Calibration procedure by pressing
Play
.
3
Continues on next page
Product manual - IRB 8700
815
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued