Note
Article number
Equipment, etc.
Fully threaded
-
Screw M16x80
Content is defined in section
.
-
Standard toolkit
Required consumables
Note
Article number
Consumable
Molykote 1000
Unloading the pressure of the balancing device
Use these procedures to unload the pressure of the balancing device.
Preparations before unloading the pressure of balancing device
Note
Action
xx1500002310
Jog the robot to calibration position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
2
Unloading the pressure of the balancing device
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Continues on next page
548
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.6.4 Unloading and restoring the balancing device
Continued
Summary of Contents for IRC5 Compact