Disconnecting the brake release unit
Note
Action
DANGER
Make sure that all supplies for electrical power, hy-
draulic pressure, and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
read the safety information in section
2
Take a picture or make notes of how the robot cabling
is positioned in regard to the brake release board.
3
xx1300000670
Use caution and remove the connectors X8, X9 and
X10 from the brake release board.
4
Removing the brake release unit
Note
Action
DANGER
Make sure that all supplies for electrical power, hy-
draulic pressure, and air pressure are turned off.
1
Unscrew the attachment screws securing the brake
release unit bracket.
2
xx1300000744
Remove the bracket with the brake release unit fitted.
3
Continues on next page
244
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the brake release unit
Continued