3.3.14 Inspecting the signal lamp (option)
Location of signal lamp
The signal lamp is located as shown in this figure.
Required tools and equipment
Note
Article number
Equipment
To be replaced if damage is detected.
See
Signal lamp kit
Content is defined in section
-
Standard toolkit
Inspecting, signal lamp
Use this procedure to inspect the function of the signal lamp.
Note
Action
Inspect that signal lamp is lit when motors are put in
operation ("MOTORS ON").
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working area.
2
Article number is specified in
quired tools and equipment on
page 138
.
If the lamp is not lit, trace the fault by:
•
inspecting whether the signal lamp is broken.
If so, replace it.
•
inspecting cable connections.
•
inspecting the cabling. Replace the cabling if
a fault is detected.
3
138
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
3 Maintenance
3.3.14 Inspecting the signal lamp (option)
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Product manual IRB 8700 ...
Page 16: ...This page is intentionally left blank ...
Page 824: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 840: ...This page is intentionally left blank ...
Page 846: ......
Page 847: ......