Refitting the SMB/BU cables
Note
Action
O-ring: 21522012-429
xx1300000737
Inspect the o-ring located on the SMB/BU
cover is undamaged. Replace if damaged.
1
Wipe clean the contact surfaces of the
cover as well as the hole it shall fit in.
2
Fit the o-ring.
3
Sikaflex
Apply Sikaflex on top of the o-ring, on the
SMB/BU cover.
4
xx1500003089
Carefully run the cables for SMB and brake
release units into the SMB recess.
5
Attachment screws M6x16 (4 pcs)
xx1500003086
Use caution and refit the SMB/BU cover in
its hole from inside the SMB recess without
damaging the o-ring.
Note
Do not tighten the screws fully. It must still
be possible to adjust the position of the
cable harness by rotating the SMB/BU
cover in its hole a little.
6
Continues on next page
220
Product manual - IRB 8700
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness
Continued
Summary of Contents for IRC5 Compact
Page 1: ...ROBOTICS Product manual IRB 8700 ...
Page 16: ...This page is intentionally left blank ...
Page 824: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 840: ...This page is intentionally left blank ...
Page 846: ......
Page 847: ......