Note
Action
Attachment screws: M5x12 8.8 (7 pcs)
xx1200001135
Refit the motor cover with its attachment
screws.
Note
Do not reuse the self-threading attachment
screws. Replace with standard attachment
screws or the threads will be damaged.
Note
Make sure the o-ring is undamaged and
properly fitted.
8
Make sure that the covers are tightly
sealed.
9
Refitting the cabling
Use this procedure to refit the cabling.
Note
Action
Use caution and push the cable harness
into the lower arm.
1
xx1200001282
Refit the
axis-2 lower arm metal clamp
and
the
axis-3 lower arm metal clamp
located
on the inside of the lower arm.
Note
The screws are reached from the outside
of the lower arm!
2
xx1200001283
Refit the cable bracket on the frame.
3
Continues on next page
Product manual - IRB 6700
731
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.8.4 Replacing the axis-2 gearbox (IRB 6700 - 300/2.70, IRB 6700 - 245/3.00)
Continued