Removing the cable harness - base, frame and lower arm
These procedures describes how to remove the cable harness from base, frame
and lower arm.
Preparations before removing the cable harness in the base
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1300000561
Remove the base cover.
2
xx1300000591
Disconnect connectors:
•
R1.MP
•
R1.SMB
3
xx1400000366
If used, disconnect the DressPack hoses
in the base.
4
Continues on next page
246
Product manual - IRB 6700
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued
Summary of Contents for IRB 6700 - 150/3.20
Page 1: ...ROBOTICS Product manual IRB 6700 ...
Page 46: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 786: ...This page is intentionally left blank ...
Page 812: ...This page is intentionally left blank ...
Page 836: ...This page is intentionally left blank ...
Page 838: ...This page is intentionally left blank ...
Page 845: ......