Maintenance 45
5. Replace the cooling fan. Make sure that
the air flow direction is correct, towards
the bottom of the power module.
Tightening torque for the screws is 2
N
⋅
m.
6. Connect the fan connector and reinstall
the fan assembly plate. Tightening
torque for the fan assembly plate
screws is 9 N
⋅
m.
7. Close the cover plate of the power
section.
8. After the inverter starts, make sure that
there are no fan failure warnings. You
can read the status of each fan from parameter group 202
Fan control
.
Replacing the control section cooling fan
The control section cooling fan is located at the top of the control section.