Maintenance 35
Firmware upload using Drive Loader 2
The firmware upload process is controlled by the Drive Loader 2 tool. Do not stop or
cancel the process while it runs, as doing so can corrupt the memory in the control unit of
the inverter, and prevent further operation.
To upload the firmware:
1. On the host PC: Start up the Drive Loader 2 tool.
2. Press
Open
and select firmware package
LP_Firmware.lp
from the unzipped firmware
package. After reading the firmware package, Drive Loader 2 initiates a port scan to
identify the connected inverter. As a result of the scan, the tool indicates a connected
ACS880 inverter. This is actually either the PVS980 Solar inverter or the PVS800-57B
Solar inverter.
3. Make sure that the firmware versions and details of the scan are correct. The serial
port is dependent on the computer in use. If there are multiple possible ports, verify the
correct port from the Device manager of the computer.
4. Click
Download
to initiate the firmware update process. Click
OK
to acknowledge the
warning message about not disturbing the load process. The progress bar indicates
remaining time of the load process.
WARNING!
Do not unplug the USB cable while uploading the firmware. Also
make sure the PC has enough battery life or is connected to power mains. If the
upload is interrupted, the Flash memory stick might have to be replaced.
5. Click
OK
after the firmware is updated successfully. The Drive Loader 2 reads
information from the inverter. The tool might indicate a warning for the current
firmware versions. Ignore the warning at this point (firmware on the PC and in the
inverter are identical).
6. Close the Drive Loader 2 tool.
After a successful firmware upload
1. Unplug the mini-USB.
2. The Control unit launches to the language options.
3. Select your preferred language.
4. Press
OK
.
5. After the Control unit has rebooted, check the new firmware details from
Main menu
>
Systems info
>
Drive
. Scroll down until the FW version is shown. Check that the FW
version is same as in the firmware zip file.
Restoring data from a backup
Restore configuration data and energy production data after SW upload.
Summary of Contents for Fimer PVS980-58-4348kVA-I
Page 1: ...Central inverter PVS980 58 From 4348 to 5000 kVA Commissioning and maintenance manual ...
Page 4: ...2 ...
Page 16: ...14 Safety instructions ...
Page 20: ...18 Introduction to the manual ...
Page 26: ...24 Electrical commissioning ...
Page 56: ...54 Maintenance ...