Appendix A – CoE Object Dictionary 123
Note:
The Transparent and ABB Drives command values cannot
be changed with an SDO write service.
Drive parameter access via CoE objects
Drive parameters can be accessed via objects 0x4001…0x4063.
The 8 least significant bits of the object index correspond to the
drive parameter group and the sub-index is the drive parameter
index.
Examples:
•
Object 0x400A:02 = drive par. 10.02
•
Object 0x4033:0F = drive par. 51.15
4001
0
Group 1
U8
R
Drive parameter
group 1
1
Parameter
1.01
Drive parameter 1.01
Drv
2
Parameter
1.02
Drive parameter 1.02
Drv
… …
…
…
…
…
…
…
… …
…
…
…
…
…
4063
Group 99
U8
R
Drive parameter
group 99
1
Parameter
99.01
Drive parameter
99.01
Drv
… …
…
…
…
…
…
Index
Subindex
Bit
15…8
7…0
8…0
Value
0x40
Drive par. group (hex)
Drive par. index (hex)
Index SI
Name
Type
Ac-
cess
PM
Information
NVS