ETL600 Commissioning Report
EN
C7/C10
HE
Test
No.
Test procedure
Test point
Permissible
value
Units
Test
result
C.11.5 Pax
4-wire
Mark if configured:
N11
[ ]
N22
[ ]
N54
[ ]
Test E-Wire:
Close and open at
Remote equ. at terminal,
telephony 4a-4b
Terminal, telephony
3a-3b
E-Wire must toggle
N11
[ ]
N22
[ ]
N54
[ ]
Measure Output level.
Feed 800 Hz with
configured input level of
remote PAX (Default:
-3.5 dBm).
(Activate at terminal,
telephony 4a-4b)
Feed into rem. equ. at
terminal, telephony
1a-1b
Measure at terminal,
telephony 2a-2b
Configured Output
level ±1 dB
(Def.: -3.5 dBm)
dBm
(600
Ω
) N11:
___________
N22:
___________
N54:
___________
PAX-BLOCKING normal
Measure at terminal,
telephony 6a-6b,
6b-7a
6a-6b is open
6b-7a is closed
N11
[ ]
N22
[ ]
N54
[ ]
PAX-BLOCKING
blocked
Interrupt local loop, wait
about 30 sec.
Measure at terminal,
telephony 6a-6b,
6b-7a
6a-6b is closed
6b-7a is open
N11
[ ]
N22
[ ]
N54
[ ]
C.11.6 Pax
4/2-wire
Mark if configured:
N11
[ ]
N22
[ ]
N54
[ ]
Test E-Wire:
Close and open at
terminal, telephony
4a-4b
Terminal, telephony
3a-3b
E-Wire must toggle
N11
[ ]
N22
[ ]
N54
[ ]
Measure Output level at
AF1.
Feed 800 Hz with
configured input level
(Def.: -3.5 dBm).
(Activate at terminal,
telephony 4a-4b)
Feed into terminal,
telephony 1a-1b
Measure at terminal,
telephony 2a-2b
Configured Output
level ±1 dB
(Def.: -3.5 dBm)
dBm
(600
Ω
) N11:
___________
N22:
___________
N54:
___________
Measure Output level at
PAX2W.
Feed 800 Hz with
configured input level
(Def.: -3.5 dBm).
(Activate at terminal,
telephony 4a-4b)
Feed into terminal,
telephony 1a-1b
Measure at terminal,
telephony 8a-8b
Configured Output
level ±1 dB
(Def.: -7.0 dBm)
dBm
(600
Ω
) N11:
___________
N22:
___________
N54:
___________
Test Local/Transit:
Measure Output level at
AF1.
Feed 800 Hz with
configured input level of
PAX2W (Def: -0.0 dBm).
Activate terminal,
telephony 5a-4b and
4a-4b.
Feed into rem. equ. at
terminal, telephony
8a-8b
Measure at terminal,
telephony 8a-8b
Configured Output
level ±1.5 dB
(Def.: -7.0 dBm)
dBm
(600
Ω
) N11:
___________
N22:
___________
N54:
___________
© ABB Switzerland Ltd
Form 1KHw001495-EN
Rev. A
Summary of Contents for ETL600
Page 4: ......
Page 32: ......
Page 126: ......
Page 176: ......
Page 206: ......
Page 216: ......
Page 226: ......
Page 264: ......
Page 268: ......
Page 276: ......
Page 284: ......
Page 308: ......
Page 324: ......
Page 346: ......
Page 348: ......
Page 366: ......
Page 372: ......
Page 374: ......
Page 380: ......