ABB Switzerland Ltd
1KHW001489-EN
ETL600
4.4.5.1. Communication
media
The PC with the HMI600 acts as client and must have an
internet/intranet access.
A second PC acting as server and satisfying the requirements given in
section 4.2.1, with the server program SVR600 installed. The PC
should have a free COM port and internet/intranet access via network
card.
Two modems compliant to the requirements given in section 4.4.3.1.1.
For the connection between modem and server PC, a 9 pole 1:1
modem cable (female to male) is required. In case the COM port of the
PC has a 25 pole RS-232 connector, an adapter (25 pole female to 9
pole male) is needed.
For the connection between modem and ETL600, a 9 pin null modem
cable as described in section 4.4.3.1.2 must be used.
4.4.5.2. Communication
settings
A good way of setting up a combined internet/phone modem
connection to an ETL600 is to proceed in the following steps:
Take into operation the phone modem connection between server PC
and ETL600 by installing HMI600
on the server PC
and proceeding
as described in section 4.4.3.
Install the server program SVR600 on the server PC and configure it
as described in section 4.4.5.2.1. Configure the HMI600 on the server
PC as described in section 4.4.4.2.2 and logon to the equipment as
described in section 4.4.3.3.
Close the HMI600 on the server PC leaving SVR600 running,
configure the HMI600 on the client PC with the same settings (also
referring to section 4.4.4.2.2) and logon to the equipment as described
in section 4.4.3.3.
4.4.5.2.1.
Configuration of SVR600
Start-up SVR600 on the server PC and click the button
Settings
. Set
the communication mode (
Comm. mode
) to
Modem (dialling)
,
choose the correct modem in the field
Select device
and accept the
default values in the other fields:
Server port:
5111
Inactivity timeout:
3600
seconds
Timeout:
10000
seconds
Start the server program by pressing the button
Start server
. By
clicking the minimize button, the SVR600 application window
disappears and the icon
SVR
appears instead in one of the corners of
the screen. The colour of the icon changes depending on the status of
the SVR600 (stopped, not connected, connected, read/write).
4-10
November 2005
User Interface Program
Summary of Contents for ETL600
Page 4: ......
Page 32: ......
Page 126: ......
Page 176: ......
Page 206: ......
Page 216: ......
Page 226: ......
Page 264: ......
Page 268: ......
Page 276: ......
Page 284: ......
Page 308: ......
Page 324: ......
Page 346: ......
Page 348: ......
Page 366: ......
Page 372: ......
Page 374: ......
Page 380: ......