The following IP addresses are reserved:
•
192.168.125.83 (Service Box)
•
192.168.125.1 (Controller Service Port)
en1600001560
Note
If the Service Box is configured as Gateway, then LAN Setup can be changed to
match the connection to multiple controller, devices or PLC for Remote Access.
WARNING
If the Service port is a DHCP server, it is recommended to connect the equipments
with a predefined static IP. For example, an integrated PLC equipments can be
connected with 192.168.125.200 IP predefined on LAN3.
Initial installation for security
Securing the local authorization of Remote Access
Note
Due to security reasons the Remote Access mode is enabled only if the digital
input of the Service Box is switched ON. An option is provided in a kit to connect
a key, or this can be done on site to connect to an external switch key.
Continues on next page
Product manual - Connected Services
117
3HAC060439-001 Revision: E
© Copyright 2019 ABB. All rights reserved.
7 Remote Access
7.4 Customer site configuration
Continued
Summary of Contents for DSQC1016