2 Installation
2.6.1. Installation of Water and air unit
3HAC027309-001 Revision: D
116
©
Co
py
rig
h
t 200
6-
201
0 ABB. All righ
ts reser
v
ed.
Location of Water and air unit, type Sb (SpotPack Basic)
The Water and air unit type Sb is located as shown in the figure below. The figure shows the
water and air unit fitted on IRB 6600, but the principle is the same for the other models.
xx0800000115
General technical data, type S and Sb
The table below shows technical data of the water and air pressure:
The table below shows technical data for water and air quality:
A
Water and air unit, type Sb
B
Connection box
C
Bracket, connection box
D
Bracket right (Bracket left on other side. Not shown here)
E
Clamp holder with plastic clamp
PROC 1 PROC 1 on robot base
PROC 2 PROC 2 on robot base
PROC 3 PROC 3 on robot base
PROC 4 PROC 4 on robot base (option)
Parameter
Value
Water operating pressure Max. 0.6 MPa / 87 PSI
Air operating pressure
Max. 1.0 MPa / 145 PSI
Parameter
Value
Water quality
Normal filtered industrial water quality, 80 to 100 mesh.
Air quality
Use clean air.
When there is excessive condensate, install a device that will
eliminate water, such as a dryer or water separator (Drain Catch)
on the inlet side of the air filter.
Continued