![ABB Advant Controller 450 User Manual Download Page 64](http://html.mh-extra.com/html/abb/advant-controller-450/advant-controller-450_user-manual_3016064.webp)
$GYDQW
&RQWUROOHU8VHU¶V*XLGH
&KDSWHU ,QWURGXFWLRQ
1-34
3BSE 002 415R701 Rev A
)XQFWLRQDO6XUYH\
•
Reports for Adva Command or MasterView 800/1
•
Functional units, binary
1
•
•
Functional units, adaptive self-tuning PID loop control, PIDCONA
•
Functional units, motor and valve control, group start
•
Trend data storage
•
Status list
•
Group alarm
•
Adva Command or MasterView 800/1 support.
0DVWHU%DWFK6XSSRUW4&%$7
The optional program module QC07-BAT41 extends the functionality given by the basic system
program module with functions listed below.
QC07-BAT41 adapts the Advant Controller 450 to the advanced batch functionality offered by a
MasterBatch 200/1.
)XQFWLRQDO6XUYH\
•
MasterBatch 200/1 support.
8VHU'HILQHG3&(OHPHQWV4&8'3
The optional program module QC07-UDP41 extends the functionality given by the basic
system program module with the possibility to define your own library of user defined PC
elements. The user defined PC element is created in the Advant Station 100 Series Engineering
Station and built-up of a combination of normal PC elements found in the standard PC elements
libraries of the Advant Controller 450. After the user defined PC element is installed in the
Advant Controller 450 it can be used freely in all PC programs as a normal PC element.
These elements will appear in every sense as standard PC elements.
2EMHFW6XSSRUWYLD$GYDQW)LHOGEXV4&&20
The optional program module QC07-COM41 can provide AIS, DIS, MB, MI, MIL and MR
objects in Advant Controller 110/160 to be operated from the operator station
(Advant Station 500 Series or AdvaSoft for Windows).
Following functions are supported:
•
Acknowledgment of events
•
Blocking of events and alarms
•
Blocking of process data update
•
Blocking of process data value.
1.
Only the presentation and dialog support are included in QC07-OPF41. The PC elements and corresponding data
base are included in QC07-BAS41 and QC07-LIB42.
Summary of Contents for Advant Controller 450
Page 1: ...Advant OCS with Master software GYDQW RQWUROOHU User s Guide 3BSE 002 415R701 Rev A ...
Page 26: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xvi ...
Page 30: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xx ...
Page 488: ... GYDQW RQWUROOHU 8VHU V XLGH SSHQGL DUGZDUH 0RGXOHV A 48 3BSE 002 415R701 Rev A ...
Page 508: ...Advant Controller 450 User s Guide Appendix D Item Designations D 12 3BSE 002 415R701 Rev A ...
Page 518: ...Advant Controller 450 User s Guide Appendix F Load Calculation F 4 3BSE 002 415R701 Rev A ...
Page 522: ...Advant Controller 450 User s Guide Appendix G Memory Calculation G 4 3BSE 002 415R701 Rev A ...
Page 528: ...Advant Controller 450 User s Guide Appendix H Halt Codes H 6 3BSE 002 415R701 Rev A ...
Page 562: ...Advant Controller 450 User s Guide Index iv 3BSE 002 415R701 Rev A ...
Page 563: ......
Page 564: ...3BSE 002 415R701 Rev A March 2000 ...