![ABB Advant Controller 450 User Manual Download Page 137](http://html.mh-extra.com/html/abb/advant-controller-450/advant-controller-450_user-manual_3016137.webp)
$GYDQW
&RQWUROOHU8VHU¶V*XLGH
6HFWLRQ $YDLODELOLW\DQG6HFXULW\
3BSE 002 415R701 Rev A
1-107
For further discussion of various aspects of reliability, availability and security, see separate
documentation. Some keywords follow:
•
Solid mechanical and electrical construction
•
Security against electrical interference
•
High-quality components
•
Well-tested electronic units
•
Thoroughly developed and tested modular software
•
Easily interpreted program language for application programs, AMPL
•
Complete documentation
•
Integral supervision and diagnostic functions
•
Powerful tools for testing
•
On-line replacement of faulty hardware units
•
After-sale service
•
Redundancy.
Below you can find important information regarding security. Descriptions of the provided
diagnostics and the possibilities of redundancy in the Advant Controller 450 also follow.
3URFHVV2XWSXWV%HKDYLRUDW,QWHUUXSWV
From the viewpoint of security, the behavior of the control outputs to the process in connection
to ordered or unintentional interrupts is very important.
Advant OCS has a straightforward philosophy: all process outputs are controlled to zero (loss of
elevated zero) and relay outputs are de-energized.
Unintentional interrupts are caused, for example, by the following events:
•
Fault in central processing unit and memory
•
Loss of power supply
•
Fault in power supply
•
Fault in parallel bus communication (backplane bus on CPU and I/O subrack).
In spite of the fact that an Advant Controller 450 is a very reliable system, reset of outputs to
zero cannot be guaranteed during all conditions. Always assume a combination of errors or an
incorrect system handling which can cause an output to behave in an unexpected way. This is of
great importance when it comes to personnel safety and preventing expensive technical
equipment from being damaged.
'XSOLFDWLRQIRU6HFXULW\
Duplication of control system functions is one way to ensure that all tasks are performed
correctly. It is, however, very important to emphasize that the security in a process control
system, when it comes to personnel safety, must never be based on duplication of system
functions alone. You must always consider other measures as well.
Summary of Contents for Advant Controller 450
Page 1: ...Advant OCS with Master software GYDQW RQWUROOHU User s Guide 3BSE 002 415R701 Rev A ...
Page 26: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xvi ...
Page 30: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xx ...
Page 488: ... GYDQW RQWUROOHU 8VHU V XLGH SSHQGL DUGZDUH 0RGXOHV A 48 3BSE 002 415R701 Rev A ...
Page 508: ...Advant Controller 450 User s Guide Appendix D Item Designations D 12 3BSE 002 415R701 Rev A ...
Page 518: ...Advant Controller 450 User s Guide Appendix F Load Calculation F 4 3BSE 002 415R701 Rev A ...
Page 522: ...Advant Controller 450 User s Guide Appendix G Memory Calculation G 4 3BSE 002 415R701 Rev A ...
Page 528: ...Advant Controller 450 User s Guide Appendix H Halt Codes H 6 3BSE 002 415R701 Rev A ...
Page 562: ...Advant Controller 450 User s Guide Index iv 3BSE 002 415R701 Rev A ...
Page 563: ......
Page 564: ...3BSE 002 415R701 Rev A March 2000 ...