$GYDQW
&RQWUROOHU8VHU¶V*XLGH
&KDSWHU ,QWURGXFWLRQ
1-14
3BSE 002 415R701 Rev A
,1680
,Q
tegrated
6
ystem for
8
ser optimized
0
otor control. An ABB proprietary, LONWORKS based
system for switchgear and motor control systems.
,QWULQVLFDOO\6DIH(TXLSPHQW
Intrinsically safe equipment and wiring is equipment and wiring which is incapable of releasing
sufficient electrical energy under normal or abnormal conditions to cause ignition of a specific
hazardous atmosphere mixture.
/('/
ight
(
mitting
'
iode
/RFDO&RQWURO
local operator
Local control is a mode of operation where responsibility is assigned to an operator/equipment
located in the process environment close to the process object.
/21:25.6
A fieldbus developed and owned by Echelon Corporation, and with a public protocol.
0RGXOH
A module is a hardware unit, with or without accommodated software, or a software unit.
There are modules of various sizes and functionality. Examples of hardware modules:
6XEUDFNVXEPRGXOHFDUULHU
, communication module, I/O module.
Examples of software modules:
Basic system program module in a controller, a PC element.
0XOWLGURS&RQQHFWLRQ
A multi-drop connection is a means of establishing a multi-drop network, that is a network with
two endpoint
QRGHV
, any number of intermediate
QRGHV
and only a single path between any two
QRGHV
.
1RGH
A node in general - a point in a data network.
A node in an application:
•
Any logically addressable unit directly connected to the plant or
FRQWUROQHWZRUN
.
Examples are controller, process station, operator station.
•
Any logically addressable unit connected via RCOM.
2EMHFW2ULHQWHG&RQQHFWLRQ
Object oriented connection means a way of organizing the connection of field intermediate
cables from process objects which utilize different categories of signals, for example, DI and
DO. The purpose is to eliminate the need of marshalling and cable split-up.
2IIOLQH
With off-line configuration, configuration data is created outside the application for later
installation, or the internal configuration data is directly affected, but the application is inactive.
2QOLQH
With on-line configuration, the internal configuration data of a system application is directly
affected, while the application is active.
3URFHVV2EMHFW
A process object is process concept/equipment, for example, valve, motor, conveyor, tank.
3URFHVV6WDWLRQ
Process station is a descriptive name for MasterPiece products.
A process station is an entity in which control applications are running. It includes the process
I/O.
Summary of Contents for Advant Controller 450
Page 1: ...Advant OCS with Master software GYDQW RQWUROOHU User s Guide 3BSE 002 415R701 Rev A ...
Page 26: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xvi ...
Page 30: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xx ...
Page 488: ... GYDQW RQWUROOHU 8VHU V XLGH SSHQGL DUGZDUH 0RGXOHV A 48 3BSE 002 415R701 Rev A ...
Page 508: ...Advant Controller 450 User s Guide Appendix D Item Designations D 12 3BSE 002 415R701 Rev A ...
Page 518: ...Advant Controller 450 User s Guide Appendix F Load Calculation F 4 3BSE 002 415R701 Rev A ...
Page 522: ...Advant Controller 450 User s Guide Appendix G Memory Calculation G 4 3BSE 002 415R701 Rev A ...
Page 528: ...Advant Controller 450 User s Guide Appendix H Halt Codes H 6 3BSE 002 415R701 Rev A ...
Page 562: ...Advant Controller 450 User s Guide Index iv 3BSE 002 415R701 Rev A ...
Page 563: ......
Page 564: ...3BSE 002 415R701 Rev A March 2000 ...