Materials
Hot-dip zinc-coated (thickness approx. 20 µm) steel sheet (thickness 1.5 mm) with
polyester thermosetting powder coating (thickness approx. 80 µm) on visible sur-
faces. Color: RAL 7035 (light beige, semi-gloss).
Color of the side panels: RAL 9017 (black, semi-gloss)
Cabinet
Painted or tin- or silver-plated copper or aluminum
Busbars
Aluminum, acid-fast stainless steel, PA pipes
Internal cooling circuit pip-
ing
IP42 filter (Air-Tex G-150): 5158 × 520 × 12 mm (ABB code: 64665324)
Air filters (door)
Insulating materials and non-metallic items: Mostly self-extinctive
Fire safety of materials
(IEC 60332-1)
Frame: Wood or plywood. Plastic wrapping: PE-LD. Bands: PP or steel.
Packaging
The main parts of the converter can be recycled to preserve natural resources and
energy. Product parts and materials should be dismantled and separated.
Generally all metals, such as steel, aluminum, copper and its alloys, and precious
metals can be recycled as material. Plastics, rubber, cardboard and other packaging
material can be used in energy recovery. Printed circuit boards and large electro-
lytic capacitors need selective treatment according to IEC 62635 guidelines. To
aid recycling, plastic parts are marked with an appropriate identification code.
Contact your local ABB distributor for further information on environmental aspects
and recycling instructions for professional recyclers. End of life treatment must
follow international and local regulations.
Disposal
Auxiliary circuit current consumption
Auxiliary circuit current consumption varies depending on the size of the converter and
selected options. For detailed information, contact your local ABB representative.
94 Technical data
Summary of Contents for ACS880-77CC
Page 1: ...ABB WIND TURBINE CONVERTERS ACS880 77CC wind turbine converters Hardware manual...
Page 2: ......
Page 4: ......
Page 10: ...10...
Page 17: ...5 1 3 4 6 8 7 2 Safety instructions 17...
Page 22: ...22...
Page 40: ...40...
Page 60: ...60...
Page 73: ...2a 3b 4c 5 Air flow direction is towards the converter module Maintenance 73...
Page 104: ...104...
Page 108: ...Description CAN bus connection XCAN XCAN 108 BCU x5 control unit...
Page 112: ...112 Dimension drawings...
Page 113: ...Dimension drawings 113...
Page 114: ...114 Dimension drawings...
Page 126: ...126...