Place cables into the slot.
Keep cables on the right of the side plate.
7.
Connect the fan power cable.
7
8. Carefully put the fan cover into position in the drive. Make sure that the fan
power cable is routed correctly. Push the cover to lock into position.
8
■
To replace the cooling fan for frame size R3
WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or
death, or damage to the equipment can occur. If you are not a qualified
electrical professional, do not do installation, commissioning or
maintenance work.
1.
Stop the drive and do the steps in section
before you start the work.
2.
Use a suitable flat screwdriver to open the fan cover.
Maintenance 85