Refer to
The Safe torque off function (page 143)
STO interface
(SGND, S+, S1, S2)
Brake resistor connection data
The brake resistor output is conditionally short-circuit proof by
IEC/EN 61800-5-1 and UL 61800-5-1.
Short-circuit protec-
tion (IEC 61800-5-1,
IEC 60439-1,
UL 61800-5-1)
Rated conditional short-circuit current is as defined in IEC 60439-1.
Energy efficiency data (ecodesign)
Energy efficiency data according to IEC 61800-9-2 is available from the ecodesign
tool (
https://ecodesign.drivesmotors.abb.com/
Energy efficiency data is not provided for the 1~230 V drives. The drives with one
phase input are not in the scope of the EU ecodesign requirements (Regulation
EU/2019/1781) or the UK ecodesign requirements (Regulation SI 2021 No. 745).
Degrees of protection
IP20 (cabinet installation): Standard enclosure. The drive must be
installed in a cabinet to fulfill the requirements for shielding from
contact.
Degree of protection
(IEC/EN 60529)
UL Open Type. For indoor use only.
Enclosure types (UL
61800-5-1)
lll
Overvoltage category
(IEC 60664-1)
l
Protective classes
(IEC/EN 61800-5-1)
Ambient conditions
Environmental limits for the drive are given below. The drive must be used in a
heated indoor controlled environment.
120 Technical data
Summary of Contents for ACS180
Page 1: ...ABB MACHINERY DRIVES ACS180 drives Hardware manual...
Page 2: ......
Page 4: ......
Page 12: ...12...
Page 36: ...36...
Page 41: ...4 Tighten the mounting screws Mechanical installation 41...
Page 58: ...58...
Page 76: ...76...
Page 90: ...90...
Page 130: ...Frame R0 130 Dimension drawings...
Page 131: ...Frame R1 Dimension drawings 131...
Page 133: ...Frame R3 Dimension drawings 133...
Page 134: ...Frame R4 134 Dimension drawings...
Page 142: ...142...
Page 162: ...Declarations of conformity 162 The Safe torque off function...
Page 163: ...The Safe torque off function 163...
Page 164: ...164 The Safe torque off function...
Page 165: ...The Safe torque off function 165...
Page 166: ...166...