Note: As standard, the drive contains capacitors connected between the main
circuit and the frame. These capacitors and long motor cables increase the ground
leakage current and may cause nuisance faults in residual current devices.
Implementing the Emergency stop function
For safety reasons, install the emergency stop devices at each operator control
station and at other operating stations where emergency stop may be needed.
Design the emergency stop according to the applicable standards.
You can use the Safe torque off function of the drive to implement the Emergency
stop function.
Note: Pressing the stop (off) key on the control panel of the drive does not generate
an emergency stop of the motor or separate the drive from dangerous potential.
Implementing the Safe torque off function
See chapter
The Safe torque off function (page 143)
Using a safety switch between the drive and the motor
ABB recommends to install a safety switch between the permanent magnet motor
and the drive output. The switch is needed to isolate the motor from the drive
during maintenance work on the drive.
Implementing the control of a contactor between drive and
motor
Implementing the control of the output contactor depends on the motor control
mode and stopping method selected.
When you select the vector motor control mode and the motor ramp stop mode,
use this operation sequence to open the contactor:
1.
Give a stop command to the drive.
2.
Wait until the drive decelerates the motor to zero speed.
3.
Open the contactor.
WARNING!
If vector motor control mode is in use, do not open the output contactor
while the drive controls the motor. The motor control operates faster than
the contactor, and tries to maintain the load current. This can cause damage
to the contactor.
56 Guidelines for planning the electrical installation
Summary of Contents for ACS180
Page 1: ...ABB MACHINERY DRIVES ACS180 drives Hardware manual...
Page 2: ......
Page 4: ......
Page 12: ...12...
Page 36: ...36...
Page 41: ...4 Tighten the mounting screws Mechanical installation 41...
Page 58: ...58...
Page 76: ...76...
Page 90: ...90...
Page 130: ...Frame R0 130 Dimension drawings...
Page 131: ...Frame R1 Dimension drawings 131...
Page 133: ...Frame R3 Dimension drawings 133...
Page 134: ...Frame R4 134 Dimension drawings...
Page 142: ...142...
Page 162: ...Declarations of conformity 162 The Safe torque off function...
Page 163: ...The Safe torque off function 163...
Page 164: ...164 The Safe torque off function...
Page 165: ...The Safe torque off function 165...
Page 166: ...166...