50
q
Request the FC-
i
scales to reply with the F-Function settings.
Command
? F C , 0 5 0 1 C
R
L
F
Request the setting of
f-05-01
.
Reply
F C , 0 5 0 1 , 0 C
R
L
F
f-05-01
=
0
Command
? F C C
R
L
F
Request to reply with the setting of the next F-Function.
Reply
F C , 0 5 0 2 , 0 C
R
L
F
f-05-02
=
0
q
Store the specified F-Function setting value
Command
F C , 0 5 0 3 , + 1 2 3 4 C
R
L
F
Set “1234” as the Upper limit.
F-Function number:
4 digits
Setting value:
Maximum 8 digits including sign.
Reply
AK
Command
O N C
R
L
F
Start with new settings.
Reply
AK
Having finished the "FC" command, send the "ON" command to start the scale with
new settings. The scale replies <AK> (06H) and starts.
F-# Setting value
F-# Setting value