11-2. Data Output Mode
11-2. Data Output Mode
11-2. Data Output Mode
11-2. Data Output Mode
q
The data output modes and parameters are set by F-Functions in
f-06
f-06
f-06
f-06
/
07
07
07
07
/
08-
08-
08-
08-
X
as
described in the F-Function parameters, section 9.
q
To control the scale using commands from an external device, refer to “
11-5.
11-5.
11-5.
11-5.
Command Mode
Command Mode
Command Mode
Command Mode
”.
q
Refer to “
11-5. Command Mode
11-5. Command Mode
11-5. Command Mode
11-5. Command Mode
” about the output data format.
Data Out Mode (
Data Out Mode (
Data Out Mode (
Data Out Mode (
f-06
f-06
f-06
f-06
////
07
07
07
07
////
08-01
08-01
08-01
08-01
))))
q
Key Mode (
f-06/07/08-01
f-06/07/08-01
f-06/07/08-01
f-06/07/08-01
="
0
")
When the weight display is stable, data is sent by pressing the
key.
The count display will blink when the data has been sent.
q
Stream Mode (
f-06
f-06
f-06
f-06
/
07
07
07
07
/
08-01
08-01
08-01
08-01
="
1
11
1
")
Data is sent continuously. The data-update rate is approximately 10 times per
second for
f-06
f-06
f-06
f-06
/
07
07
07
07
/
08-03
08-03
08-03
08-03
="
2
22
2
". This rate is same as the display-update rate. For
f-
f-
f-
f-
06
06
06
06
/
07
07
07
07
/
08-3
08-3
08-3
08-3
="
1
11
1
" or "
2
22
2
", the interval between continuous data is approximately 1.6
seconds.
q
Auto-print Mode A (
f-06
f-06
f-06
f-06
/
07
07
07
07
/
08-01
08-01
08-01
08-01
="
2
22
2
")
Data is sent if the WEIGHT display is stable at +5d (weighing display division) and
above. Next transmission can not occur until after the weight display falls below +5d.
q
Auto-print Mode B (
f-06
f-06
f-06
f-06
/
07
07
07
07
/
08-01
08-01
08-01
08-01
="
3
33
3
")
Data is sent if the WEIGHT display is stable at ±5d (weighing display division) and
above/below. Next transmission can not occur until after the weight display falls
between –5d and +5d.
Data to be Sent (
Data to be Sent (
Data to be Sent (
Data to be Sent (
f-06
f-06
f-06
f-06
////
07
07
07
07
////
08-02
08-02
08-02
08-02
))))
Select which data is o be sent by keying in a
0
or
1
for the data: Date / time, ID No.,
PCS (count), weight or unit weight.
Example:
Key in
0
1
1
0
0
to display
01100
, this setting would send only the
ID number and the count.
Unit weight
Weight
PCS (count)
ID
Date / time
#
#
#
#
#
#
#
f-06-02
&&
F?I
C o m p a r a t o r
12345678C000045678id-0
01100
!
2 3 S A M U U W ( g ) 1 2 C l e a r I D
12345670.0000045678901234567
‘
0
’ not to send data
‘
1
’ to send data