Set PP.00 to 0000 if the user password is not necessary.
If you want to set the user password, input a 4-digit number, press
FUNC/DATA to confirm. If not pressing any key within 5 minutes, the
password will become effective.
Changing the password:
Press PRG, input the old password, and then select PP.00 ( at this time
PP.00
=
0000 ) , input new password and press FUNC/DATA to confirm.
The password will become effective if not pressing any key within 5
minutes.
Note
:
Please learn the password by heart.
PP.01 is to set the mode of write-in protection of parameters.
0: All parameters are allowed to be changed;;
1: No parameters can be changed except the P0.04 and PP.01;
2: No parameters can be changed except PP.01.
0: disabled
1: clear fault record
Clear the contents of PL.14~PL.19.
2: restore to factory defaults
If PP.02 is set at 2, the parameters listed before PL.14 except P1.00 and
P1.09will be restored to factory defaults..
After the initialization, the parameter will change to 0 automatically.
7.19 Factory Default ( PU )
PP.01 Write-in protection
Range: 0
~
2
【
0
】
PP.02 Parameter initialization
Range: 0
~
2
【
0
】
PP.03~PP.06 Reserved
Reserved
PU.00 User password
****