A-TS
17
https://a-ts.cn/en/
Item
Description
function
Command
channel
Via operation panel, terminals and serial port
Frequency setting
channel
Digital setting, AIand communication
Auxiliary
frequency setting
Flexible auxiliary frequency selectable
Analog output
terminals
0/4
~
20mA and 0/2
~
10V ( selectable )
Protection function
Phase loss failure protection, Over/Under
current protection,
Over/Under voltage protection,
Overheat and overload protection.
Environment
Operating
environment
In-door, no direct sunlight, no dust, no corrosive
gas or
combustible gas,no oil mist, vapor, drip, or
salinity.
Altitude
Less than 1000m ( Above 1000m derating )
Ambient
temperature
-10
℃~+
40
℃
, derating is required from 40
~
50
℃
;
Above 40
℃
, each degree rised, derating 2%;
Highest temperature: 50
℃
.
Humidity
Less than 95% RH, no condensing
Vibration
Less than5.9m/s
2
( 0.6g )
Storage
temperature
-40
℃~+
70
℃
Enclosure
Protection level
IP20
Cooling
Fan cooling, natural cooling
Mounting mode
Mounted in the cabinet
4.2 Products Series Introduction
4.2.1 DT100 Models