Fault
Code
Displayed
Description
Cause
Lockout
type
Remedy
E15
Blower speed
abnormal.
Blower speed is 200RPM
below the target speed for
20 seconds.
Soft
Check the blower wire harness.
Change the blower.
Change the board.
1.
2.
3.
E16
Blower speed is 500RPM
above the target speed for 6
seconds.
E17
Machine starts or normal
combustion, but Blower
speed = 0 for last 3sec.
E18
Have Blower’s output signal
but the Blower speed = 0 for
last 400ms.
E19
Blower speed stuck > 3000
rpm
Soft
E20
Proportional
valve (PV) current
unusual.
Proportional valve Current <
Minimum.
Soft
Check the proportional gas valve
wire harness.
Change the board.
Change the gas valve assembly.
1.
2.
3.
E21
Proportional valve Current >
Maximum.
E22
Outlet
Temperature
Probe is Open
circuit.
Outlet Temperature
is < minimum de
fi
ned
temperature.
Soft
Check temperature probes wire
harness.
Replace themperature probe.
Change the board.
1.
2.
3.
E23
Outlet
Temperature
Probe is Short
circuit.
Outlet Temperature
is > maximum de
fi
ned
temperature.
E24
Inlet Temperature
Probe is Open
circuit.
Inlet Temperature is
< minimum de
fi
ned
temperature.
E25
Inlet Temperature
Probe is Short
circuit.
Inlet Temperature
is > maximum de
fi
ned
temperature.
E26
Tank Temperature
Probe is Open
circuit.
Tank Temperature
is < minimum de
fi
ned
temperature.
E27
Tank Temperature
Probe is Short
circuit.
Tank Temperature
is > maximum de
fi
ned
temperature.
E28
Ignition failure.
After a failure to detect
the
fl
ame during ignition,
the control will retry the
speci
fi
ed number of times.
After the maximum failed
attempts, this fault is
declared.
Soft
Check the igniter wire harness.
Check igniter 120Vac voltage
supply during the ignition time.
Check the ignition rod. If it looks
dirty clean it using isopropyl alcohol
and a clean cloth.
Check the high voltage wiring
connection between igniter and
igniter rod for proper contact.
1.
2.
3.
4.
E29
Outlet water
temperature too
low.
Outlet water temperature <=
(setting temperature – 15°C)
for 60 seconds after
fl
ame
detected.
Alert
Check the outlet temperature probe.
Change the board.
1.
2.
TABLE 5
Summary of Contents for HYB-90N
Page 4: ...4 www hotwater com 316888 001 Rev 00 dRaFt Jun 28 245 GENERAL SAFETY...
Page 25: ...316888 001 Rev 00 dRaFt Jun 28 245 www hotwater com 25 FIGURE 31...
Page 52: ...599 Hill Street West Fergus ON Canada N1M 2X1 PHONE 1 888 479 8324 www hotwater com...
Page 109: ...www hotwater com 57 NOTES...
Page 110: ...58 www hotwater com NOTES...
Page 111: ...www hotwater com 59 NOTES...
Page 112: ...599 rue Hill Ouest Fergus ON Canada N1M 2X1 PHONE 1 888 479 8324 www hotwater com...