![3Ware 720-0192-00 Manual Download Page 69](http://html1.mh-extra.com/html/3ware/720-0192-00/720-0192-00_manual_3236248069.webp)
Chapter 2. CLI Syntax Reference
61
3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.2
autoverify
attribute enables the autoverify attribute on the unit that is to be
created. For more details on this feature, see “/cx/ux set autoverify=on|off” on
page 92. This feature is not supported on model 7000/8000. For 9650SE and
9690SA controllers that support basic verify, autoverify will be set to ON by
default for a new unit. For other 9000-series controllers that do not support
basic verify, autoverify is set to OFF by default for a new unit.
noqpolicy
attribute instructs CLI to disable the qpolicy (drive queuing for
SATA drives only) on the newly created unit. The default is for the qpolicy to
be on (in other words, noqpolicy is not specified). For a spare unit, drive
queuing is not meaningful, so the noqpolicy cannot be set. During unit
creation, specifying
noqpolicy
for a spare returns an error. (If the spare unit
becomes a true unit, it will adopt the qpolicy of the “new” unit.) For more
about drive queuing, see “/cx/ux show qpolicy” on page 86 and “/cx/ux set
qpolicy=on|off” on page 96.
ignoreECC
attribute enables the ignoreECC/OverwriteECC attribute on the
unit that is to be created. For more details on this feature, see “/cx/ux set
ignoreECC=on|off” on page 96. The following table illustrates the supported
Model-Unit Types. This table only applies to setting this feature at unit
creation time. IgnoreECC only applies to redundant units.
For the 7/8000
series, this setting is only applicable during rebuild; it is not applicable
during creation.
name=string
attribute allows you to name the new unit. (This feature is for
9000 series and above controllers.) The string can be up to 21 characters and
cannot contain spaces. In order to use reserved characters (‘<‘, ‘>’, ‘!’, ‘&’,
etc.) put double quotes (" ") around the name string. The name can be changed
after the unit has been created. For more information, see
“/cx/ux set
name=string” on page 96
and “/cx/ux show name” on page 85.
storsave=protect|balance|perform
attribute allows user to set the storsave
policy of the new unit. This feature is only for 9000 series SX/SE/SA
controllers. For more information, see “/cx/ux set
storsave=protect|balance|perform [quiet]” on page 97.
Table 8: Supported Model-Unit Types for ignoreECC
Model
R-0
R-1
R-5
R-6
R-10
R-50
Single
Spare
JBOD
7K/8K
No
No
No
N/A
No
No
No
No
No
9000
a
a. Models 9500S, 9550SX, and 9590SE
No
Yes
Yes
N/A
Yes
Yes
No
No
No
9650SE
and
9690SA
No
Yes
Yes
Yes
Yes
Yes
No
No
No
Summary of Contents for 720-0192-00
Page 3: ......