![3Ware 720-0192-00 Manual Download Page 132](http://html1.mh-extra.com/html/3ware/720-0192-00/720-0192-00_manual_3236248132.webp)
Enclosure Object and Element Commands
www.3ware.com
124
/c
x
/e
x
/pwrs
x
show
/c
x
/e
x
/pwrs
x
/ show identify
/c
x
/e
x
/pwrs
x
set identify=on|off
/c
x
/e
x
/temp
x
show
/c
x
/e
x
/temp
x
show identify
/c
x
/e
x
/temp
x
set identify=on|off
/c
x
/e
x
/alm
x
show
/c
x
/e
x
/alm
x
set alarm=mute|unmute|off
/c
x
/e
x
show
This command is used with the 9690SA controller. For the 9650SE and CCU
enclosure, simply drop the prepended controller name in the command and
use /e
x
.
This command shows summary information on the specified enclosure /
cx/ex.
This report consists of several parts, depending on the available elements of
the enclosures. Typically, the summary consists of the
Enclosure
section
listing the set of enclosures, a
Fan
section, a
Temperature Sensor
section, a
Power Supply
section, a
Slot
section, and an
Alarm
section.
Example:
//localhost> /c0/e0 show
Encl Status
---------------------------
/c0/e0 OK
Fan Status State Step RPM Identify
------------------------------------------------------------
fan0 OK ON 1 2670 Off
fan1 OK ON 1 9500 Off
fan2 OK ON 1 8540 Off
fan3 OK ON 1 2830 Off
fan4 OK ON 1 9120 Off
fan5 OK ON 1 8330 Off
TempSensor Status Temperature Identify
--------------------------------------------------------
temp0 OK 41C(105F) Off
temp1 OK 38C(100F) Off
temp2 OK 34C(93F) Off
temp3 OK 38C(100F) Off
temp4 OK 38C(100F) Off
temp5 OK 34C(93F) Off
temp6 NOT-INSTALLED - Off
temp7 NOT-INSTALLED - Off
PowerSupply Status State Voltage Current Identify
---------------------------------------------------------------------------
pwrs0 OK on OK OK Off
pwrs1 OK on OK OK Off