background image

2

3

ENGLISH

W  

WARNING

This product helps protect against certain airborne contaminants. 

Misuse may result in sickness 

or death.

 For proper use, see supervisor, 

User Instructions

 or call 3M in U.S.A., 1-800-243 4630. In 

Canada, call Technical Service at 1-800-267-4414.

FOREWORD

Contact Information

Read all instructions and warnings before using. Keep these 

User Instructions

 for reference. If you have questions 

regarding these products, contact 3M Technical Service.

In United States: 

Website: www.3M.com/PPESafety 

Technical Service: 1-800-243-4630

In Canada: 

Website: www.3M.com/CA/PPESafety 

Technical Service: 1-800-267-4414

System Description

The 3M™ Versaflo™ S-Series Hoods and Headcovers are designed to be used with certain 3M™ Breathing Tubes 

and Powered Air-Purifying Respirators or Supplied Air Units to form a respirator system.  
The S-100 series headcovers (i.e. loose fitting facepieces) and the S-400 and S-500 series hoods have a wide-view 

window (visor) and an elasticized faceseal. The S-403 has an added inner bib or shroud which is worn tucked into 

work clothing. The hoods and headcovers are held in place with an adjustable, non-replaceable plastic integrated 

suspension (S-133, S-433, and S-533) or a sewn-in elastic suspension (S-103 and S-403). There are different sizes 

and fabrics available, and all headcovers and hoods are supplied fully assembled, ready for use. 
The S-600, S-700, and S-800 series hoods incorporate a neck collar or inner bib with an outer shroud and a wide-

view visor. They are available in a variety of fabrics. The S-800 series hoods have sealed seams to help prevent liquid 

permeation through the thread holes. The S-600, S-700, and S-800 series hoods use the S-950 Premium Head 

Suspension. The S-950 suspension is easily removable and can be adjusted by the user for fit and airflow comfort.  

W

 WARNING

Properly selected, used, and maintained respirators help protect against certain airborne contaminants by reducing 

concentrations in the wearer’s breathing zone below the Occupational Exposure Limit (OEL). It is essential to follow 

all instructions and government regulations on the use of this product, including wearing the complete respirator 

system during all times of exposure, in order for the product to help protect the wearer. 

Misuse of respirators may 

result in overexposure to contaminants and lead to sickness or death.

 For proper use, see supervisor, refer to 

the product 

User Instructions

 or contact 3M Technical Service.

List of Warnings within these 

User Instructions

W

 WARNING

1.  This product helps protect against certain airborne contaminants. 

Misuse may result in sickness or death.

 

For proper use, see supervisor, 

User Instructions 

or call 3M in U.S.A., 1-800-243-4630. In Canada, call Technical 

Service at 1-800-267-4414.

2. 

Failure to follow these instructions may reduce respirator performance, overexpose you to contaminants, 

and may result in injury, sickness, or death.

•  Always correctly position the S-100, S-400, and S-500 series hoods and loose-fitting facepieces on the head.  
•  Users should be clean-shaven where the respirator’s faceseal (S-100, S-400, and S-500 series products) 

comes into contact with their face. 

•  Always tuck the inner shroud of the S-403, S-607, S-707, and S-807 hood into your work clothes. 
•  Always pull the S-950 premium head suspension fully through the opening in the S-600, S-700, and S-800 

series hoods.  

•  Do not use with parts or accessories other than those manufactured by 3M as described in these 

User 

Instructions

 or on the NIOSH approval label for this respirator. 

•  The S-Series hoods and headcovers are one component of an approved respiratory protection system. Always 

read and follow all 

User Instructions

 supplied with your 3M PAPR Blower Unit or Supplied Air Unit in order to 

ensure correct system operation. 

3. 

Do not use these products for eye and face protection. When exposed to eye and face hazards (e.g. 

impact hazards) select and wear appropriate protection. Failure to do so may result in serious injury. 

 

4. 

Do not use these products around heat, flames, or sparks. Select and wear appropriate protection when 

exposed to sparks and/or flames. Failure to do so may result in serious injury.

 In case of intended use in 

explosive atmospheres, contact 3M Technical Service. 

Limitations of Use

1.  Do not wear this respirator to enter areas where:

a.  Atmospheres are oxygen deficient, 
b.  Contaminant concentrations are unknown,
c.  Contaminant concentrations are Immediately Dangerous to Life or Health (IDLH),
d.  Contaminant concentrations exceed the maximum use concentration (MUC) determined using the Assigned 

Protection Factor (APF) for the specific respirator system or the APF mandated by specific government 

standards, whichever is lower. See 

APF

 section of these 

User Instructions

.

2.  These products may offer limited splash protection against certain chemicals. Consult a qualified industrial 

hygienist and the applicable Chemical Permeation Guide(s) to determine suitability of these products for your 

specific environment. Note, only the S-800 series hoods have sealed seams to help prevent liquid permeation 

through thread holes. For additional information, contact 3M Technical Service. 

Respirator Program Management  

Occupational use of respirators must be in compliance with applicable health and safety standards. By law, US 

employers must establish a written respiratory protection program meeting the requirements of the OSHA Respiratory 

Protection Standard 29 CFR 1910.134 and any applicable OSHA substance specific standards. In Canada, CSA 

standard Z94.4 requirements must be met and/or requirements of the applicable jurisdiction, as appropriate. For 

additional information on this standard, contact OSHA at www.OSHA.gov. The major sections of 1910.134 are listed 

here for convenience, but should not serve as a substitute for consulting the actual regulation or contacting OSHA. 

Consult an industrial hygienist or call 3M Technical Service with questions concerning applicability of these products to 

your job requirements.

Major Sections of OSHA 29 CFR 1910.134

Section 

Description

A

Permissible Practice

B

Definitions

C

Respiratory Protection Program 

D

Selection of Respirators

E

Medical Evaluation

F

Fit Testing

G

Use of Respirators

H

Maintenance and Care of Respirators

I

Breathing Air Quality and Use

J

Identification of Cartridges, Filters, and Canisters

K

Training and Information

L

Program Evaluation

M

Recordkeeping

NIOSH –Approval, Cautions, & Limitations 

These products are one component of a NIOSH approved respiratory protection system. Refer to the 

User Instructions

 

and/or the NIOSH approval label provided with the 3M™ Powered Air Purifying Blower Unit or Supplied Air Unit for 

approved configurations and applicable NIOSH Cautions and Limitations.

OPERATING INSTRUCTIONS

Unpacking

Inspect the package contents for shipping damage and ensure all components are present. The product should be 

inspected before each use, following the procedures in the 

Inspection

 section of these 

User Instructions

.  

Assembly

W

 WARNING

Failure to follow these instructions may reduce respirator performance, over expose you to contaminants, 

and may result in sickness or death.

•  Always pull the S-950 premium head suspension fully through the opening in the S-600, S-700, and S-800 

series hoods.

S-100, S-400, S-500 Series (with Integrated Head Suspension) 

These products are provided fully assembled. Prior to use, ensure any protective covering or film that may have been 

placed over the visor to protect it during manufacturing and shipping is removed. Verify all plastic suspension straps 

(S-133, S-433, and S-533 series) are fully connected prior to use. Re-connect if necessary.

Summary of Contents for Versaflo S Series

Page 1: ...S S 403L S 433S S 433L S 533S S 533L IMPORTANT Before use the wearer must read and understand these User Instructions Keep these User Instructions for reference IMPORTANT Avant de se servir du produit...

Page 2: ...cking 3 Assembly 3 Donning Fitting 5 Entering and Exiting the Contaminated Area 8 INSPECTION MAINTENANCE 8 REPLACEMENT PARTS AND ACCESSORIES 9 S 950 Premium Head Suspension 9 CLEANING STORAGE AND DISP...

Page 3: ...lied Air Unit in order to ensure correct system operation 3 Do not use these products for eye and face protection When exposed to eye and face hazards e g impact hazards select and wear appropriate pr...

Page 4: ...Cover is only used with the S 950 Premium Head Suspension and is not compatible with the S 100 S 400 or S 500 series products The S 955 may be installed and removed from the breathing tube as needed...

Page 5: ...ary to achieve a comfortable fit Fig 8 The headband of the plastic suspension should be worn around your forehead and the crown strap should be positioned on top of the head not around the back of the...

Page 6: ...may reduce respirator performance overexpose you to contaminants and may result in injury sickness or death Do not use with parts or accessories other than those manufactured by 3M as described in the...

Page 7: ...o catches one on each side of the headband Fig 19a 2 Install the chin strap by inserting the chin strap clips onto the attachment points on the suspension according to Fig 19b Firmly press the hole in...

Page 8: ...y Disposal Dispose of product according to local regulations The integrated plastic components head suspension and air inlet of the S 133 S 433 and S 533 series can be removed for disposal Fig 21a 21b...

Page 9: ...Premium Head Suspension S 955 Airflow Adjustment Cover S 954 Size Reducing Pad S 923 Peel Off S 857 Assembly Contains S 807 Hood with Inner Shroud S 950 Premium Head Suspension S 955 Airflow Adjustmen...

Page 10: ...RRANTY OF QUALITY EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT LIMITATION OF LIABILITY Except as provided above 3M shall not be liable or responsible for any loss or damage whether direct indirect...

Page 11: ...p rieure S 950 dans l ouverture des cagoules des s ries S 600 S 700 et S 800 Ne pas l utiliser avec des pi ces ou des accessoires autres que ceux qui sont fabriqu s par 3M comme l expliquent les pr se...

Page 12: ...it d air Fig 2 Fig 3 Fixer la coiffe aux languettes de la visi re situ es de chaque c t de la fen tre de la visi re en glissant les pinces de fixation de la visi re dans les languettes de la visi re F...

Page 13: ...us amples renseignements Pour toute question au sujet des tailles communiquer avec le service technique de 3M Tableau 1 Lignes directrices g n rale de choix de la taille pour les cagoules et protecteu...

Page 14: ...ui sont tellement petit que vous pourriez ne pas tre en mesure de les voir ou de les sentir 2 Ne pas porter ce respirateur en pr sence des conditions ci dessous a Atmosph res d ficientes en oxyg ne b...

Page 15: ...1 Retirer le coussinet confort existant en tirant d licatement le coussinet l ext rieur des points de fixation 2 S curiser le nouveau coussinet confort S 953 Fig 14 la coiffe selon la Fig 15 Les deux...

Page 16: ...utilisateur peut vouloir plier les languettes sur le seconde troisi me et quatri me prot ge lentille peler empil s comme l illustre la Fig 20 Laisser la languette du premier dessus prot ge lentille n...

Page 17: ...910 134 Communiquer avec le Service technique de 3M pour obtenir des proc dures d essai et des donn es de soutien LISTE DES COMPOSANTS ACCESSOIRES ET PI CES DE REMPLACEMENT Cagoules et protecteurs de...

Page 18: ...mplacer sans frais toute pi ce d fectueuse du respirateur Versaflo 3M conform ment aux directives ci dessous et trouv par 3M comme tant d fectueux au moment de l achat ou pendant la p riode de garanti...

Page 19: ...7 Desempacado 37 Armado 38 Colocaci n y ajuste 40 Entrada y salida del rea contaminada 42 INSPECCI N MANTENIMIENTO 43 PARTES DE REPUESTO Y ACCESORIOS 43 Arn s premium S 950 43 LIMPIEZA MANTENIMIENTO Y...

Page 20: ...serie S 600 S 700 y S 800 No use con partes o accesorios distintos a los fabricados por 3M como se describe en estas Instrucciones o en la etiqueta de aprobaci n del NIOSH para este producto Las cubie...

Page 21: ...en la leng eta Fig 3 Remoci n del arn s premium Para quitar el arn s S 950 desabroche los clips del anexo del visor de cada lado del arn s en la ventana del visor al levantar la leng eta central del c...

Page 22: ...A Si es posible use el sistema de trabajo en pareja y que un colega le ayude a la revisi n de la colocaci n correcta Serie S 100 S 400 y S 500 Jale la capucha o cubierta para la cabeza de modo que el...

Page 23: ...n y mantenimiento de estas Instrucciones para obtener una gu a de c mo cuidar adecuadamente la capucha o cubierta para la cabeza INSPECCI N MANTENIMIENTO W ADVERTENCIA No seguir estas instrucciones p...

Page 24: ...posici n en los dos puntos de conexi n Fig 18 Reemplazo de la banda para la cabeza S 951 Para remplazar la banda para la cabeza S 951 libere la banda de los puntos de sujeci n ubicados en los clips d...

Page 25: ...tes que contengan lanolina u otros aceites Limpie el visor con solventes fuertes como MEK acetona o tolueno ya que puede da ar y distorsionar el equipo Sumerja los componentes en soluciones o solvente...

Page 26: ...ubierta despegable S 922 S 757 37301 El ensamble contiene Capucha para pintor con Recubrimiento interior Arn s Premium S 950 Cubierta para ajuste de aire S 955 Almohadilla reductora de tama o S 954 y...

Page 27: ...I N En Estados Unidos Internet www 3M com PPESafety Internet www 3m com mx saludocupacional O llame a 3M en su localidad Los productos 3M PSD s lo est n dise ados para uso ocupacional PREF CIO DO INTR...

Page 28: ...ho Sempre puxe a suspens o carneira Premium S 950 na sua totalidade atrav s da abertura dos capuzes das s ries S 600 S 700 e S 800 N o use pe as ou acess rios outros que n o sejam os fabricados pela 3...

Page 29: ...de veda o do duto de ar i e anel de veda o Fig 2 Fig 3 Fixe a suspens o carneira s ling etas guias do visor localizadas nas laterais da janela do visor deslizando os clipes de fixa o sobre a aba Fig...

Page 30: ...alguma d vida sobre dimensionamento entre em contato com o Servi o T cnicoda 3M Tabela 1 Diretrizes para Tamanhos para Capuzes e Toucas da S rie S Circunfer ncia da Cabe a cm 50 51 52 53 54 55 56 57 5...

Page 31: ...pensos no ar que podem ser perigosos para a sua sa de incluem aqueles que s o t o pequenos que voc n o pode v los e nem cheir los 2 N o use este respirador para entrar em reas em que A atmosfera apres...

Page 32: ...com cuidado a almofada de seus pontos de fixa o 2 Fixe a nova Tira de Suor Standard conforto S 953 Fig 14 suspens o carneira de acordo com a Fig 15 As duas fendas na almofada de conforto prendem se a...

Page 33: ...com o revestimento adesivo contra o per metro do visor NOTA Para ajudar a facilitar a remo o cada camada individual da pel cula em uso os usu rios os usu rios podem querer dobrar as abas na segunda t...

Page 34: ...3M suporta o FPA de 1 000 para estes capuzes o que est de acordo com as normas da OSHA sobre FPA definidos na norma 29 CFR 1910 134 Contate com o Servi o T cnico ou ADS da 3M para apoiar nos procedime...

Page 35: ...por ocasi o da compra e garantir as pe as listadas abaixo pelos per odos indicados desde que sejam mantidas e usadas de acordo com o Manual de Instru es e ou recomenda es de para o produto A nica obri...

Page 36: ......

Page 37: ...e 3M Canada C P 5757 London Ontario N6A 4T1 3M 2015 Tous droits r serv s 3M et Versaflo sont des marques de commerce de 3M utilis es sous licence au Canada 3M M xico S A de C V Av Santa Fe No 190 Col...

Reviews: