Flash-hook Maximum
(msec)
Set this value to define the maximum time the hook
switch can be depressed for the NBX system to
recognize the event as a valid flash hook signal. If the
hook switched is depressed longer than this time, the
NBX system treats the event as if you had hung up the
telephone.
Default:
Depends on the country in which the NBX
system is operating.
When you load a regional pack (
Operations
>
Regional Software
) and select the tones and cadences
appropriate for your location (
System Configuration >
System Settings > Regional Settings > Advanced
), the
default value is set on your NBX system.
Minimum:
0 msec
Maximum:
2000 msec
Supervisory Disconnect
Pulse (msec)
Set this value to define the duration of the supervisory
disconnect pulse (battery denial) that disconnects the
current call.
Default:
Depends on the country in which the NBX
system is operating.
When you load a regional pack (
Operations
>
Regional Software
) and select the tones and cadences
appropriate for your location (
System Configuration >
System Settings > Regional Settings > Advanced
), the
default value is set on your NBX system.
Minimum:
0 (this setting disables the function)
Maximum:
2000 msec
Table 41
Analog Terminal Adapter - Advanced Settings Parameters (continued)
Field
Purpose
Summary of Contents for SuperStack 3 NBX
Page 14: ......
Page 18: ...18 ABOUT THIS GUIDE...
Page 26: ...26 CHAPTER 1 INTRODUCTION...
Page 138: ...138 CHAPTER 2 DIAL PLAN...
Page 322: ...322 CHAPTER 3 DEVICE CONFIGURATION...
Page 328: ...328 CHAPTER 4 USER CONFIGURATION...
Page 412: ...412 CHAPTER 10 TROUBLESHOOTING...
Page 458: ...458 APPENDIX B ISDN COMPLETION CAUSE CODES...
Page 480: ...480 GLOSSARY...
Page 492: ...492 INDEX...