set arp agingtime
Changes the aging timeout for dynamic ARP entries.
Syntax
—
set arp agingtime
seconds
seconds
— Number of seconds an entry can remain unused before
MSS removes the entry. You can specify from 0 through 1,000,000.
To disable aging, specify 0.
Defaults
— None.
Access
— Enabled.
History
— Introduced in MSS Version 3.0.
Usage
— Aging applies only to dynamic entries.
To reset the ARP aging timeout to its default value, use the
set arp
agingtime 1200
command.
Examples
— The following command changes the ARP aging timeout to
1800 seconds:
WX1200#
set arp agingtime 1800
success: set arp aging time to 1800 seconds
The following command disables ARP aging:
WX1200#
set arp agingtime 0
success: set arp aging time to 0 seconds
See Also
set arp
on page 158
telnet
on page 195
Summary of Contents for OfficeConnect WX1200
Page 36: ...36 CHAPTER 2 ACCESS COMMANDS...
Page 62: ...62 CHAPTER 3 SYSTEM SERVICE COMMANDS...
Page 200: ...200 CHAPTER 7 IP SERVICES COMMANDS...
Page 264: ...264 CHAPTER 8 AAA COMMANDS...
Page 272: ...272 CHAPTER 9 MOBILITY DOMAIN COMMANDS...
Page 392: ...392 CHAPTER 11 MANAGED ACCESS POINT COMMANDS...
Page 444: ...444 CHAPTER 13 IGMP SNOOPING COMMANDS...
Page 468: ...468 CHAPTER 14 SECURITY ACL COMMANDS...
Page 484: ...484 CHAPTER 15 CRYPTOGRAPHY COMMANDS...
Page 532: ...532 CHAPTER 18 SESSION MANAGEMENT COMMANDS...
Page 588: ...588 CHAPTER 20 FILE MANAGEMENT COMMANDS...
Page 596: ...596 CHAPTER 21 TRACE COMMANDS...
Page 608: ...608 CHAPTER 22 SNOOP COMMANDS...
Page 618: ...618 CHAPTER 23 SYSTEM LOG COMMANDS...