Chapter 1 SNMP Configuration Commands
1-12
undo snmp-agent local-engineid
View
System view
Parameter
engineid
: Specifies the engine ID with a character string, only composed of 10 to 64
hexadecimal numbers. Two hexadecimal characters form an octet.
Description
Use the
snmp-agent local-engineid
command to set the engine ID of the local SNMP
entity.
Use the
undo
snmp-agent local-engineid
command to restore the default setting.
By default, the device engine ID is "Enterprise device information". Device
information is determined according to different products. It can be an IP address, MAC
address or user-defined hexadecimal numeral string.
Related command:
snmp-agent usm-user
.
Example
# Configure the local device name as 1234512345.
<3Com>system-view
System View: return to User View with Ctrl+Z.
[3Com] snmp-agent local-engineid 1234512345
1.1.13 snmp-agent mib-view
Syntax
snmp-agent mib-view
{
included
|
excluded
}
view-name oid-tree
undo snmp-agent mib-view
view-name
View
System view
Parameter
included:
Includes the MIB subtree.
Excluded
: Excludes the MIB subtree.
view-name: View name. It is a character string, ranging from 1 to 32 characters.
oid-tree
: The OID MIB subtree of the MIB object subtree. It is a character string, ranging
from 1 to 255 characters. It can be a character string of the variable OID (such as