Chapter 1 Login Commands
1-22
Description
Use the
stopbits
command to set the stop bits of the user interface.
Use the
undo stopbits
command to revert to the default stop bits.
Use these two commands in the AUX user interface only.
By default, the stop bits is 1.
Note:
Changing the value of the stop bits does not affect the communications.
Example
# Set the stop bits to 2.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] user-interface aux 0
[3Com-ui-aux0] stopbits 2
1.1.24 sysname
Syntax
sysname
string
undo sysname
View
System view
Parameter
string
: Domain name of the switch. This argument can contain 1 to 30 characters and
defaults to “3Com”.
Description
Use the
sysname
command to set a domain name for the switch.
Use the
undo sysname
command to revert to the default domain name.
The CLI prompt reflects the domain name of a switch. For example, if the domain
name of a switch is “3Com”, then the prompt of user view is <3Com>.
Example
# Set the domain name of the switch to “ABC”.