3Com Switch 7750 Series
Command Reference Guide – System Maintenance & Debugging
Chapter 3 Device Management
Commands
3-5
Example
# Display the CPU usage of the card on slot 0 of the switch.
<3Com> display cpu slot 0
Board 0 CPU busy status:
18% in last 5 seconds
19% in last 1 minute
19% in last 5 minutes
Table 3-2
Description on the fields of the
display cpu
command
Field
Description
CPU busy status
Indicates that the following lines describe the CPU
occupancies in different time periods.
18% in last 5 seconds
19% in last 1 minute
19% in last 5 minutes
The CPU usage in the last five seconds is 18%.
The CPU usage in the last one minute is 19%.
The CPU usage in the last five minutes is 19%.
3.1.7 display device
Syntax
display
device
[
detail
| [
shelf
shelf-no
] [
frame
frame-no
] [
slot
slot-number
] ]
View
Any view
Parameter
detail
: Detail information about the specified switch.
shelf-no
: Shelf number of a switch.
frame-no
: Frame number of a switch.
slot-number
: Slot number of a switch.
Description
Use the
display device
command to display the information, such as the module type
and operating status, about each board (main board and sub board) of a specified
switch.
You can use this command to display the following information about each board: slot
number, sub slot number, number of ports, versions of PCB, FPGA, hardware and
BootROM software, address learning mode, interface board type, and so on.