![3Com 7750 Series Command Reference Manual Download Page 882](http://html.mh-extra.com/html/3com/7750-series/7750-series_command-reference-manual_441219882.webp)
3Com Switch 7750 Series
Command Reference Guide – PoE
Chapter 2 PoE PSU Supervision Configuration Commands
2-4
Table 2-3
Description on the fields of the
display poe-power dc-output state
command
Field
Description
Normal: The DC output is normal.
Under Limit: The DC output voltage is lower than the
lower threshold.
Upper Limit: The DC output voltage is higher than the
upper threshold.
Fuse Broken: The fuse is broken.
Switch Off: The switch is off.
DC output state of the
external PoE PSU
Hardware Fault: Hardware fails.
2.1.4 display poe-power dc-output value
Syntax
display poe-power dc-output value
View
Any view
Parameter
None
Description
Use the
display poe-power dc-output value
command to display the DC output
voltage/current values of the external PoE PSUs.
Example
# Display the DC output voltage/current values of the external PoE PSUs.
<3Com> display poe-power dc-output value
DC Output Voltage : 53.997
DC Output Current : 0.350 A
Table 2-4
Description on the fields of the
display poe-power dc-output value
command
Field
Description
DC Out Voltage
DC output voltage
DC Output Current
DC output current