Malfunctions
PN series frame version
Error messages
5-6
110008,001,11-2009, jmu
5
1002
Check axis tool
T or Z is faulty
Cause
The head recognised requires an axis (T- or R-axis) for which an error was
determined after power up (check axes).=> Axis problem or wrong head
recognition.
Action
Analyse the problem if the incorrect head is displayed when the plotter is
switched on. See chapter "Head recognition code" in the description of the
electronics. If head recognition functions correctly, use test function 100
(diagnostic display) to analyse the problem for the axes and check the rele
-
vant cables and components. See chapter "Check axes" in the description
of the electronics.
1004
Head not permitted
Turn off plotter!
Cause
The head recognised is not allowed on a S-type plotter (heavy heads).
Text
Recognised head
Action
Remove the head, check the connector for the head flat cable on the Y
board. If the text displays an incorrect head type, use the "Head recognition
code" chapter in the description of the electronics to analyse the problem.
1005
Function not allowed
Job is still active
Cause
The "Select tool" option in the menu was used even though the job has not
yet ended.
Action
Allow the job to finish or delete the buffer.
1007
Tool-DST Counter
Change the tool
Cause
Work distance counter reached the maximum value.
Action
Exchange the tool and set a new maximum (ESC 2293). See the user
manual for more information about this function.
1201
Keyboard Fault
A key is pressed
Cause
Pressed key detected when plotter is switched on.
Action
Press the associated key (to release it), use test function 7 (keyboard
check) where necessary
1301
Vacuum width
Not initialised
Cause
Uninitialised vacuum width
Action
Initialise the vacuum and save the settings (see description)
1401
Error Uniboard
Axis override
Cause
The axis that is controlled by the UNI-Board is blocked or has been pushed
out of its setting position.
Action
Switch off plotter and check the axis.
1406
Error Uniboard
Axis blocked?
Cause
Axis on the UNI board did not move far enough during the axis test
Action
If "Mincurrent" (Error 1405) is also reported, solve the "Mincurrent" problem
first. If the axis was in motion prior to the axis check, switch the plotter off
and on again.
1601
Vacuum pump
Error
Cause
The temperature sensor on the vacuum pump switched the pump off.
Action
Clear error and wait until the pump starts again. If necessary, determine the
reason for the cut-out.
Содержание L-1200
Страница 6: ...PN series frame version 0 4 110002 001 11 2009 jmu 0 ...
Страница 14: ...Introduction PN series frame version Publishing details 1 8 110003 001 11 2009 jmu 1 ...
Страница 48: ...Safety PN series frame version Disposal 3 26 110005 001 11 2009 jmu 3 ...
Страница 123: ...PN series frame version Tools 7 1 100011 003 11 2009 jmu 7 7 Tools ...
Страница 124: ...Tools PN series frame version 7 2 100011 003 11 2009 jmu 7 ...
Страница 125: ...PN series frame version Tool heads 8 1 110008 001 11 2009 jmu 8 8 Tool heads ...
Страница 126: ...Tool heads PN series frame version 8 2 110008 001 11 2009 jmu 8 ...
Страница 127: ...PN series frame version Options 9 1 100015 001 11 2009 jmu 9 9 Options ...
Страница 128: ...Options PN series frame version 9 2 100015 001 11 2009 jmu 9 ...
Страница 129: ...PN series frame version Material feed 10 1 100012 003 11 2009 jmu 10 10 Material feed ...
Страница 130: ...Material feed PN series frame version 10 2 100012 003 11 2009 jmu 10 ...
Страница 131: ...PN series frame version Additional specifications 11 1 100014 003 11 2009 jmu 11 11 Additional specifications ...
Страница 132: ...Additional specifications PN series frame version 11 2 100014 003 11 2009 jmu 11 ...
Страница 133: ...PN series frame version Documents 12 1 100017 001 11 2009 jmu 12 12 Documents ...
Страница 134: ...Documents PN series frame version 12 2 100017 001 11 2009 jmu 12 ...
Страница 138: ...Annex PN series frame version Service and maintenance works 13 4 100013 003 11 2009 jmu 13 Date Signature Remarks ...
Страница 139: ...PN series frame version Annex Service and maintenance works 13 5 100013 003 11 2009 jmu 13 Date Signature Remarks ...
Страница 140: ...Annex PN series frame version Service and maintenance works 13 6 100013 003 11 2009 jmu 13 Date Signature Remarks ...
Страница 141: ...PN series frame version Annex Service and maintenance works 13 7 100013 003 11 2009 jmu 13 Date Signature Remarks ...
Страница 142: ...Annex PN series frame version Service and maintenance works 13 8 100013 003 11 2009 jmu 13 ...