User Manual for hybrid inverter HYD 10-20KTL-3PH - Rev. 1.0 of 25/08/2020
Identification: MD-AL-GI-00
Identification: MD-AL-GI-00
Rev. 4.0 of 31.01.18 - Application: GID
Disable
7. EPS Mode
7.EPS Mode
OK
1. EPS Mode
Control
OK
1.Enable
EPS
Mode
OK
2.Disable
EPS
Mode
If the PV generation (kW) > consumption (kW), with ∆P < 100W, the inverter charges the battery
(Figure 42a).
If the PV generation (kW) = consumption (kW), the inverter does not charge or discharge the battery
(Figure 42 b).
Figure 42 - Display with EPS in operation (1)
If the PV generation (kW) < consumption (kW), with ∆P < 100W, the inverter discharges the battery
(Figure 43a).
If the PV generation (kW) is normal, but consumption (kW) is lower or zero, the surplus power is
stored in the battery) (Figure 43b).
Figure 43 - Display with EPS in operation (2)
8. Communication address
8.Communication Addr
OK
1.Communication Addr
OK
a)
b)
a)
b)