24/71
User Manual for hybrid inverter HYD 10-20KTL-3PH - Rev. 1.0 of 25/08/2020
Identification: MD-AL-GI-00
Identification: MD-AL-GI-00
Rev. 4.0 of 31.01.18 - Application: GID
3.
Insert the stripped positive and negative power cables into the positive and negative metal
terminals respectively, and secure them using a suitable clamping tool. Make ensure that that
the cables are crimped so that they cannot be pulled out with force of less than 400N.
NB:
As shown, the X region cannot be compressed.
Figure 15 - Insertion of power supply
4.
Insert the secured power cables into the corresponding seats until you hear a “click” sound. The
power cables lock into place.
Figure 16 – Seat of the power cables
5.
Reinstall the cable glands on the positive and negative connectors and rotate them against the
insulating covers; check the voltage with a multimeter.
Figure 17 – Positioning of the cable gland
3)
Positive connector
4)
Negative
connector