INSTALLATION AND OPERATING INSTRUCTIONS:
Gripper, pneumatically intelligent, GPP/GPD5000-IL series
29
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
+49 7844 9138 0
●
+49 7844 9138 80
●
www.zimmer-group.com
DDOC00247 / d
EN / 2020-07-20
8.3.7 "Diagnosis" parameter
The value returned in the "Diagnosis" parameter corresponds to the error code.
Ö
Refer to the "Error diagnosis" section
Name
"Diagnosis"
Data format
UINT16
Permission
Read
Transfer
Cyclical
Value range
0 to 65535
8.3.8 "ActualPosition" parameter
The parameter "ActualPosition" corresponds to the current position of the gripper jaws relative to the full stroke.
The value is specified with a resolution of 0.01 mm.
The values can move between the "BasePosition" (minimum values) and the "WorkPosition" (maximum values).
With the position measuring system, it is possible to achieve a position accuracy of +/- 0.05 mm.
Product
Stroke per gripper
jaw
"BasePosition"
"WorkPosition"
"TeachPosition"
GPP/GPD5006IL
6 mm
0
1200
0 to 1200
GPP/GPD5008IL
8 mm
0
1600
0 to 1600
GPP/GPD5010IL
10 mm
0
2000
0 to 2000
GPP/GPD5013IL
13 mm
0
2600
0 to 2600
GPP/GPD5016IL
16 mm
0
3200
0 to 3200
GPP/GPD5025IL
25 mm
0
5000
0 to 5000
Name
"ActualPosition"
Data format
UINT16
Permission
Read
Transfer
Cyclical
Value range
0 to max. jaw stroke of the gripper
INFORMATION:
The "StatusWord" of the gripper should be used to check whether a workpiece has been gripped correctly.
Ö
The position measurement resolution is: 0.01 mm
Ö
The position measurement accuracy is: 0.05 mm
If the "ActualPosition" parameter is used for detecting the workpiece, then fluctuations around the exact value
must be taken into consideration during commissioning!