9. Service parameters
Service parameters are exchanged acyclically in each communication cycle. This data is exchanged only upon request of
the IO-Link master. Transmission of the acyclical data occurs over multiple communication cycles.
Display of the service parameters:
Parameter
Name
Data format
Permission
Transfer
0x40
"StatusWord"
UINT16
Read
Acyclical
0x41
"Diagnosis"
UINT16
Read
Acyclical
0x42
"CycleCounter"
UINT32
Read
Acyclical
0x43
"SystemTemperature" INT16
Read
Acyclical
0x44
"ControlWord"
UINT16
Read
Acyclical
0x45
"ErrorCode"
STRING
Read
Acyclical
0x46
"ErrorCounter"
UINT32
Read
Acyclical
0x47
"OperationCounter"
UINT32
Read
Acyclical
0x100
"ActualPosition"
UINT16
Read
Acyclical
0x101
"TeachPosition"
UINT16
Read
Acyclical
0x102
"WorkpieceNo."
UINT8
Read
Acyclical
0x103
"DeviceMode"
UINT8
Read
Acyclical
0x104
"PositionTolerance"
UINT8
Read
Acyclical
0x110
"ActualPressure"
UINT8
Read
Acyclical
0x111
"LowPressureError-
Threshold"
UINT8
Read/write
Acyclical
0x112
"HighPressureError-
Threshold"
UINT8
Read/write
Acyclical
0x113
"PressureHysteresis"
UINT8
Read/write
Acyclical
0x114
"BasePosition"/"Work-
Position" switching
thresholds
UINT16[4]
Read/write
Acyclical
0x115
"MovementThreshold" UINT16
Read/write
Acyclical
0x118
"HallErrorThreshold"
UINT16
Read/write
Acyclical