INSTALLATION AND OPERATING INSTRUCTIONS:
Gripper, pneumatically intelligent, GPP/GPD5000-IL series
27
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
+49 7844 9138 0
●
+49 7844 9138 80
●
www.zimmer-group.com
DDOC00247 / d
EN / 2020-07-20
8.3.5 "PositionTolerance" parameter
The PositionTolerance" parameter can be used to transmit the currently desired position detection tolerance of the work-
piece to the gripper. The entry is in mm/100 and has the same effect in the "+" direction and "-" direction.
INFORMATION:
All transmitted process data must be acquired using the "ControlWord" = 0x01 "DataTransfer."
Name
"PositionTolerance"
Data format
UINT8
Permission
Write
Transfer
Cyclical
Value range
0 to 255
WARNING:
Non-compliance may result in minor to serious injuries
Risk of injury in case of unexpected movement of the machine or system into which the gripper is to be installed.
►
Switch off the power supply to the machine before all work.
►
Secure the machine against being switched on unintentionally.
►
Check the machine for any residual energy.