54 Installation and Operating Instructions V01
10.2 AC output data
Type
TLC4000
TLC5000
TLC6000
Rated output power
4000 W
5000 W
6000 W
Max. output active power
(1)
4400 W
5500 W
6000 W
Max. output apparent power
4400 VA
5500 VA
6000VA
Rated AC voltage
3/N/PE, 220/380V, 230/400V,240/415V
Rated AC voltage range (line to line)
(2)
277 V to 512 V
Rated power frequence
50 Hz
AC power frequency
(3)
50 Hz/ 60 Hz
Operating range at AC power frequency
50 Hz
45 Hz to 55Hz
Operating range at AC power frequency
60 Hz
55 Hz to 65Hz
Rated output current at 220 V
3×6.0A
3×7.5 A
3×9.1A
Rated output current at 230 V
3×5.8 A
3×7.2 A
3×8.7 A
Rated output current at 240 V
3×5.5 A
3×6.9 A
3×8.3 A
Max. continuous output current
3×6.0 A
3×7.5 A
3×9.1 A
Power factor
VDE-AR-N 4105
0.85 ind - 0.85 cap
Other safety
>0.97 at 20% load, >0.99 at 100% load
Inrush current(peak and duration)
28A@252µs 28A@250µs
28A@253µs
Harmonic distortion (THD) at P
ac,r
< 3%
Night-time power loss
<0.6 W
Standby power loss
<12 W